RAMS for Fire Alarm Installers
Generate compliant risk assessments for fire alarm installation, commissioning, and maintenance in under 2 minutes. BS 5839, CDM 2015, WAHR 2005, and the Fire Safety Order cited automatically.
Built with UK health & safety regulations in mind
Fire alarm installation and commissioning takes place in some of the most demanding environments in the built environment: occupied offices, operational hospitals, live construction sites, and historic buildings where drilling and cable routing requires careful management. The work involves working at height in ceiling voids and on access platforms, electrical work on systems that must remain functional during installation, and close integration with other building systems (suppression, HVAC, access control).
BS 5839 Part 1 (Fire Detection and Fire Alarm Systems for Buildings) is the technical standard that governs how fire alarm systems are designed, installed, commissioned, and maintained. Any RAMS for fire alarm installation must reference BS 5839 as the design and installation basis. Where the installation takes place on a construction project, CDM 2015 applies. Where work is carried out in occupied premises, the Regulatory Reform (Fire Safety) Order 2005 imposes specific obligations on anyone who may affect the fire safety arrangements.
swiftRMS generates fire alarm installer RAMS in under 2 minutes. Input the installation environment, the work activities, and any specific hazards. The output is a compliant PDF that cites BS 5839, CDM 2015, WAHR 2005, and the Fire Safety Order, with a risk register and method statement appropriate to fire detection installation.
What Fire Alarm Installers RAMS Must Include
Compliant risk assessments for fire alarm installers work must cover these specific areas
Hot works controls for drilling and cutting
Cable routing through fire-compartment walls and floors requires core drilling. Hot works require a hot works permit, fire watch, and extinguisher provision. Compartment integrity must be maintained throughout, with approved fire-stopping reinstated at each penetration.
Isolation and partial disablement of existing systems
When working on or extending existing fire alarm systems, zones must be carefully isolated to prevent false alarms while maintaining coverage. RAMS must document the isolation procedure, the scope of the zone being disabled, and the compensatory measures (fire watch, additional patrols) required during the disablement.
Working at height in ceiling voids and on access platforms
Cable installation frequently requires working in ceiling voids, on mobile access platforms, or on fixed scaffold. WAHR 2005 applies. RAMS must specify the access equipment and justify the choice.
Electrical isolation and safe working
Fire alarm systems are low-voltage (typically 24V DC) but are connected to mains supply panels. Working on mains supply panels requires EaWR 1989 compliance. RAMS must document isolation procedure and competency requirements.
Interface with occupied premises
Where installation takes place in occupied buildings, operatives must manage public safety, maintain fire detection coverage, and avoid false alarms that could cause building evacuation. RAMS must document the notification procedure to the building manager and the occupation management plan.
COSHH for fire-stopping compounds and cable sealants
Intumescent materials, fire-stopping compounds, and cable sealing products contain chemicals that may be subject to COSHH assessment. SDS sheets must be reviewed and the relevant controls documented.
Common Fire Alarm Installers Tasks That Require RAMS
Generate RAMS for any of these tasks in minutes, not hours
New installation on a live construction site
Working alongside multiple trades in a CDM environment. RAMS must cover working in sequence with other trades, protecting partly installed systems from damage, and CDM communication with the principal contractor.
System extension in an occupied commercial building
Managing zone disablement, maintaining coverage, avoiding false alarms, and working around building occupants. The Responsible Person under the Fire Safety Order must be notified.
Detector replacement in a healthcare environment
Working in a hospital or care home requires infection prevention measures, noise controls, and coordination with estate teams. False alarms in these environments can have serious consequences.
Cable installation in ceiling voids
WAHR 2005 applies wherever ceiling access requires working at height. Suspended ceilings: weight limits, tile replacement, and fragile ceiling panel controls.
Panel installation and commissioning
Main panel, repeater panels, and network nodes. Electrical mains connection, earthing, battery backup installation, and full system commissioning test. EaWR 1989 applies to mains connection.
Maintenance and annual inspection
Servicing under BS 5839 Part 1 Section 6. Battery testing, detector cleaning, and functional testing of all devices. Working in occupied premises with controlled zone testing.
UK Legislation for Fire Alarm Installers Risk Assessments
Every RAMS automatically cites the relevant UK legislation and industry standards
BS 5839 Part 1: Fire Detection and Fire Alarm Systems for Buildings
The design and installation standard. All fire alarm installation RAMS must reference BS 5839 as the technical basis for the system being installed.
Regulatory Reform (Fire Safety) Order 2005
Anyone carrying out work that may affect the fire safety arrangements in a building has responsibilities under the Fire Safety Order. Installers working in occupied premises must not compromise fire detection coverage without appropriate compensatory measures.
Work at Height Regulations 2005 (WAHR)
Applies to cable installation in high-level ceiling voids, work on access platforms, and any task carried out above ground level.
Electricity at Work Regulations 1989 (EaWR)
Applies to connection of fire alarm systems to mains supply, work on electrical panels, and low-voltage cable installation.
CDM Regulations 2015
Fire alarm installation on construction projects requires site-specific RAMS feeding into the Principal Contractor's Construction Phase Plan.
COSHH Regulations 2002
Applies to fire-stopping compounds, sealants, and any chemical substances used during installation.
How swiftRMS Generates Fire Alarm Installers RAMS
swiftRMS generates fire alarm installer RAMS by asking about the specific installation task, the environment (new build, occupied premises, healthcare, industrial), the access requirements, and the interface with existing fire safety systems.
The output cites BS 5839 Part 1 as the installation standard, references the Fire Safety Order for occupied premises work, includes WAHR 2005 for working at height, and documents the zone isolation and compensatory fire watch procedure. Electrical work triggers EaWR 1989 controls.
The method statement section documents the installation sequence, the notification procedure to building management, and the commissioning process. The PDF is ready for submission to principal contractors, building managers, or as part of a tender document.
Frequently Asked Questions
Yes. The Responsible Person for the building under the Regulatory Reform (Fire Safety) Order 2005 must be notified before any zone is isolated, and a fire watch or compensatory measure must be agreed before disablement. The duration of disablement should be minimised, and the zone reinstated and tested at the end of each working day.
Yes, if the work is carried out above a safe working level (generally 2m or above, though lower heights can present significant fall risk). Access equipment must be suitable for the specific work: a step ladder is not appropriate for extended cable installation in a ceiling void. Mobile elevated work platforms or modular access platforms are typically more appropriate.
BAFE SP203-1 is the most widely recognised third-party certification scheme for fire detection system installation and commissioning in the UK. NSI NACOSS Gold and SSAIB accreditation are also widely accepted. Clients, building managers, and insurers will often require one of these certifications as a condition of contract.
swiftRMS currently generates RAMS for fire detection and alarm system installation. Suppression systems (sprinklers, gaseous suppression, foam) have additional requirements under LPC Technical Bulletins, BS EN 12845 (sprinklers), and specific gas suppression standards. Please contact swiftRMS for specific suppression system RAMS requirements.
Generate Your First Fire Alarm Installers RAMS Free
No credit card required. Generate a compliant, legislation-cited RAMS in under 2 minutes and download the PDF immediately.